The Urban Developer
AdvertiseEventsWebinarsUrbanity
Industry Excellence
Urban Leader
Sign In
Membership
Latest
Menu
Location
Sector
Category
Content
Type
Newsletters
Urban Leader Awards Logos RGB White
NOMINATIONS CLOSE SEPTEMBER 12 RECOGNISING THE INDIVIDUALS BEHIND THE PROJECTS
NOMINATIONS CLOSING SEPTEMBER 12 URBAN LEADER AWARDS
LEARN MOREDETAILS
TheUrbanDeveloper
Follow
About
About Us
Membership
Awards
Events
Webinars
Listings
Resources
Terms & Conditions
Commenting Policy
Privacy Policy
Republishing Guidelines
Editorial Charter
Complaints Handling Policy
Contact
General Enquiries
Advertise
Contribution Enquiry
Project Submission
Membership Enquiry
Newsletter
Stay up to date and with the latest news, projects, deals and features.
Subscribe
ADVERTISEMENT
SHARE
print
Print
Sponsored ContentPartner ContentMon 08 Nov 21

Sustainability Drives Switchgear Revolution

4d5ded87-b760-4eeb-ba03-f07577617991

Sustainability is becoming increasingly important across the building industry as companies strive to balance economic success with long-term values that support the effort to reduce climate change and ensure social progress for all stakeholders.

Sustainability objectives are put in place to progressively increase the efficiency of operations, with ambitious targets set to significantly reduce greenhouse gas emissions.

To meet the targets, all parts of the operations must contribute and carefully review all opportunities to reduce energy consumption.

It was never really considered as a realistic possibility that low-voltage switchgear designs in buildings could also contribute to these objectives.

However, as switchgear generate heat, the electrical room requires conditioning to maintain the required ambient temperatures.

Take for example an eHouse (electrical prefabricated substation), which houses low-voltage switchgear for an industrial process that runs 24-7. Maintaining the switchgear room temperature is key to the equipment performance, but also to ensure the guaranteed lifetime of all the components inside the switchgear.

This requires an appropriately sized conditioning system to be installed, which in some locations might have to run every day of the year, every hour of the day.

It is clear that the smaller the room is and the less heat the switchgear in it generates, less energy will be required for the conditioning systems.

ABB’s new switchgear NeoGear can significantly contribute to reducing the carbon footprint, thanks to the physical behaviour of laminated bus plate technology.

Traditional busbar systems generate heat due to AC-losses caused by the skin-effect in the copper bars. The absence of these AC-losses in laminated technology reduces the overall switchgear heat contribution by up to 30 per cent.

An additional contribution to more sustainable operations comes from a reduction in the energy required for room conditioning systems. The reduced heat contribution from NeoGear in an electrical room, in combination with smaller eHouses (less volume to cool), significantly reduces the amount of energy required for air conditioning.


ABB NeoGear advantages include:

  • No exposure to live parts

  • Reduces the physical switchgear footprint by up to 25 per cent

  • Increases cooling efficiency to reduce heat losses by up to 20 per cent

  • Reduces overall operational costs by up to 30 per cent through predictive maintenance, increasing uptime and performance

  • 30 unique parts vs up to 400 in traditional busbar

  • 90 per cent fewer electrical joints for highest switchgear availability

  • Arc ignition protected zones keep maintenance personnel safe.

Sustainable space utilisation

Effective space utilisation for electrical equipment is a key driver where space utilisation determines the optimum allocation of the available capex budget.

During the past decades, low-voltage switchgear has transformed from large, fully open type of installations to today’s fully enclosed, compact, modular type.

This progress came with significant improvements in safety and availability of the switchgear. However, the continuous effort to reduce switchgear footprint tended to come with a disadvantage: less space for electrical components, more difficult wiring and cable terminations and reduced rating.

What may be visually perceived as available open module space in a switchgear line-up might not always be available, due to limits of thermal performance or maximum currents per section.

With the introduction of laminated bus plate technology, it has finally become possible to reduce footprint of switchgear, yet maintain the space needed for the equipment and still offer maximum rating.

Equal performances were not possible without forced ventilation until the introduction of switchgear with laminated bus plate technology.

Thanks to this innovative technology solution, the switchgear can be up to 25 percent shorter in length and yet still allow up to 30 percent higher maximum permissible watt loss per section, all while providing the same ease of access for cabling and termination.

Innovation breeds sustainability

ABB’s latest NeoGear technology enables improved safety, energy efficiency and overall sustainability.

The laminated bus plate technology, which until now could only be found in aircraft, vehicles and space stations, helps customers keep work environments safe and meet increasing demands to reduce maintenance downtime and costs.

Download this whitepaper which introduces the laminated bus plate technology and its application in ABB’s newest low-voltage switchgear.


The Urban Developer is proud to partner with ABB to deliver this article to you. In doing so, we can continue to publish our daily news, information, insights and opinion to you, our valued readers.

InfrastructureIndustrialInternationalOpinion
AUTHOR
Partner Content
More articles by this author
ADVERTISEMENT
TOP STORIES
Stockland bumps up its apartment pipeline in melbourne and sydney
Exclusive

Stockland Re-Enters Density in $5bn Apartment Play

Renee McKeown
4 Min
Woolloongabba Precinct Vulture St
Exclusive

Brisbane Developer in Cross River Rail Compensation Tussle

Clare Burnett
4 Min
The Mondrian Gold Coast hotel's food and beverage is driving profits
Exclusive

Touch, Taste, Theatre: What’s Driving Mondrian’s Success

Renee McKeown
6 Min
Fortis’ display suites are designed as brand environments first, with tactile details and curated design to build buyer confidence before project specifics.
Exclusive

Relevant or Redundant: Will Tech Kill Display Suites?

Vanessa Croll
7 Min
Exclusive

Missing Heart: Why The Gold Coast Needs a CBD

Phil Bartsch
7 Min
View All >
South Melbourne social housing precinct
Affordable & Social Housing

South Melbourne Housing Precinct Revamp Takes Next Step

Leon Della Bosca
Stockland bumps up its apartment pipeline in melbourne and sydney
Exclusive

Stockland Re-Enters Density in $5bn Apartment Play

Renee McKeown
Aerial view of Caboolture and Bruce highway to Brisbane with Bribie Island Road crossing, Queensland, Australia
Policy

Queensland’s $2bn Push Opens New Housing Front

Vanessa Croll
First projects named in a statewide plan to fast-track supply, including thousands of homes in a major growth region…
LATEST
South Melbourne social housing precinct
Affordable & Social Housing

South Melbourne Housing Precinct Revamp Takes Next Step

Leon Della Bosca
2 Min
Stockland bumps up its apartment pipeline in melbourne and sydney
Exclusive

Stockland Re-Enters Density in $5bn Apartment Play

Renee McKeown
4 Min
Aerial view of Caboolture and Bruce highway to Brisbane with Bribie Island Road crossing, Queensland, Australia
Policy

Queensland’s $2bn Push Opens New Housing Front

Vanessa Croll
2 Min
The Adelaide purpose built student accommodation market is about to increase by 1058 beds with the State Commission Assessment Panel supporting two towers in the making.
Student Housing

Highrise Approvals Add 1000-Plus PBSA Beds in Adelaide

Renee McKeown
3 Min
View All >
ADVERTISEMENT
Article originally posted at: https://www.theurbandeveloper.com/articles/sustainability-drives-switchgear-revolution